Benefits of adding equipment

Benefits of adding equipment

Find factory fit parts and view diagrams.

Trenchers

Trenchers

1 - 16 of 20 results

Sort By

RelevanceNamePart number

Filter & Sort

RelevanceNamePart number

1 - 16 of 20 results

233-2346: T112 Manual Side Shift, Standard Chain

233-2346: T112 Manual Side Shift, Standard Chain

Designed for cutting narrow straight trenches in soil prior to laying electrical, telephone and cable lines, or water and gas pipe.



Cat

Standard Boom Length

48 in

Cutting Width

6 in

Chain Type

Standard

Required Hydraulics

Standard Flow

Overall Width

74.8 in

Overall Length

106.5 in

Weight

1076.1 lb

Overall Height

30.9 in

Optimal Hydraulic Flow

42-86 L/min (11-23 gpm)

Optimal Hydraulic Pressure

145-235 bar (2100-3400 psi)

Drive Shaft Speed at Maximum Flow

203 rpm

Side Shift Travel

22 in

Maximum Auger Clearance

21 in

Spoil Auger Diameter

18 in

Optional Cutting Widths

203, 254, 305 mm (8, 10, 12 in)


261-8560: T109 Hydraulic Side Shift, Combo Chain

261-8560: T109 Hydraulic Side Shift, Combo Chain

Designed for cutting narrow straight trenches in soil prior to laying electrical, telephone and cable lines, or water and gas pipe.



Cat

Standard Boom Length

36 in

Cutting Width

6 in

Chain Type

Combo

Required Hydraulics

Standard Flow

Overall Width

56.1 in

Overall Length

92.4 in

Weight

1099 lb

Overall Height

30.9 in

Optimal Hydraulic Flow

42-86 L/min (11-23 gpm)

Optimal Hydraulic Pressure

145-235 bar (2100-3400 psi)

Drive Shaft Speed at Maximum Flow

203 rpm

Side Shift Travel

16.5 in

Maximum Auger Clearance

21 in

Spoil Auger Diameter

18 in

Optional Cutting Widths

203, 254, 305 mm (8, 10, 12 in)


241-4252: T112 Hydraulic Side Shift, Standard Chain

241-4252: T112 Hydraulic Side Shift, Standard Chain

Designed for cutting narrow straight trenches in soil prior to laying electrical, telephone and cable lines, or water and gas pipe.



Cat

Standard Boom Length

48 in

Cutting Width

6 in

Chain Type

Standard

Required Hydraulics

Standard Flow

Overall Width

74.8 in

Overall Length

106.5 in

Weight

1121 lb

Overall Height

30.9 in

Optimal Hydraulic Flow

42-86 L/min (11-23 gpm)

Optimal Hydraulic Pressure

145-235 bar (2100-3400 psi)

Drive Shaft Speed at Maximum Flow

203 rpm

Side Shift Travel

22 in

Maximum Auger Clearance

21 in

Spoil Auger Diameter

18 in

Optional Cutting Widths

203, 254, 305 mm (8, 10, 12 in)


233-2350: T112 Manual Side Shift, Combo Chain

233-2350: T112 Manual Side Shift, Combo Chain

Designed for cutting narrow straight trenches in soil prior to laying electrical, telephone and cable lines, or water and gas pipe.



Cat

Standard Boom Length

48 in

Cutting Width

6 in

Chain Type

Combo

Required Hydraulics

Standard Flow

Overall Width

74.8 in

Overall Length

106.5 in

Weight

1154.1 lb

Overall Height

30.9 in

Optimal Hydraulic Flow

42-86 L/min (11-23 gpm)

Optimal Hydraulic Pressure

145-235 bar (2100-3400 psi)

Drive Shaft Speed at Maximum Flow

203 rpm

Side Shift Travel

22 in

Maximum Auger Clearance

21 in

Spoil Auger Diameter

18 in

Optional Cutting Widths

203, 254, 305 mm (8, 10, 12 in)


241-4251: T112 Manual Side Shift, Rock-Frost Chain

241-4251: T112 Manual Side Shift, Rock-Frost Chain

Designed for cutting narrow straight trenches in soil prior to laying electrical, telephone and cable lines, or water and gas pipe.



Cat

Standard Boom Length

48 in

Cutting Width

6 in

Chain Type

Rockfrost

Required Hydraulics

Standard Flow

Overall Width

74.8 in

Overall Length

106.5 in

Weight

1184.1 lb

Overall Height

30.9 in

Optimal Hydraulic Flow

42-86 L/min (11-23 gpm)

Optimal Hydraulic Pressure

145-235 bar (2100-3400 psi)

Drive Shaft Speed at Maximum Flow

203 rpm

Side Shift Travel

22 in

Maximum Auger Clearance

21 in

Spoil Auger Diameter

18 in

Optional Cutting Widths

203, 254, 305 mm (8, 10, 12 in)


241-4253: T112 Hydraulic Side Shift, Standard Chain

241-4253: T112 Hydraulic Side Shift, Standard Chain

Designed for cutting narrow straight trenches in soil prior to laying electrical, telephone and cable lines, or water and gas pipe.



Cat

Standard Boom Length

48 in

Cutting Width

8 in

Chain Type

Standard

Required Hydraulics

Standard Flow

Overall Width

74.8 in

Overall Length

106.5 in

Weight

1186.1 lb

Overall Height

30.9 in

Optimal Hydraulic Flow

42-86 L/min (11-23 gpm)

Optimal Hydraulic Pressure

145-235 bar (2100-3400 psi)

Drive Shaft Speed at Maximum Flow

203 rpm

Side Shift Travel

22 in

Maximum Auger Clearance

21 in

Spoil Auger Diameter

18 in

Optional Cutting Widths

152, 254, 305 mm (6, 10, 12 in)


241-4254: T112 Hydraulic Side Shift, Combo Chain

241-4254: T112 Hydraulic Side Shift, Combo Chain

Designed for cutting narrow straight trenches in soil prior to laying electrical, telephone and cable lines, or water and gas pipe.



Cat

Standard Boom Length

48 in

Cutting Width

6 in

Chain Type

Combo

Required Hydraulics

Standard Flow

Overall Width

74.8 in

Overall Length

106.5 in

Weight

1199.1 lb

Overall Height

30.9 in

Optimal Hydraulic Flow

42-86 L/min (11-23 gpm)

Optimal Hydraulic Pressure

145-235 bar (2100-3400 psi)

Drive Shaft Speed at Maximum Flow

203 rpm

Side Shift Travel

22 in

Maximum Auger Clearance

21 in

Spoil Auger Diameter

18 in

Optional Cutting Widths

203, 254, 305 mm (8, 10, 12 in)


241-4255: T112 Hydraulic Side Shift, Rock-Frost Chain

241-4255: T112 Hydraulic Side Shift, Rock-Frost Chain

Designed for cutting narrow straight trenches in soil prior to laying electrical, telephone and cable lines, or water and gas pipe.



Cat

Standard Boom Length

48 in

Cutting Width

6 in

Chain Type

Rockfrost

Required Hydraulics

Standard Flow

Overall Width

74.8 in

Overall Length

106.5 in

Weight

1229.1 lb

Overall Height

30.9 in

Optimal Hydraulic Flow

42-86 L/min (11-23 gpm)

Optimal Hydraulic Pressure

145-235 bar (2100-3400 psi)

Drive Shaft Speed at Maximum Flow

203 rpm

Side Shift Travel

22 in

Maximum Auger Clearance

21 in

Spoil Auger Diameter

18 in

Optional Cutting Widths

203, 254, 305 mm (8, 10, 12 in)


261-4806: T109 Manual Side Shift, Standard Chain

261-4806: T109 Manual Side Shift, Standard Chain

Designed for cutting narrow straight trenches in soil prior to laying electrical, telephone and cable lines, or water and gas pipe.



Cat

Standard Boom Length

36 in

Cutting Width

6 in

Chain Type

Standard

Required Hydraulics

Standard Flow

Overall Width

56.1 in

Overall Length

92.4 in

Weight

1011.9 lb

Overall Height

30.9 in

Optimal Hydraulic Flow

42-86 L/min (11-23 gpm)

Optimal Hydraulic Pressure

145-235 bar (2100-3400 psi)

Drive Shaft Speed at Maximum Flow

203 rpm

Side Shift Travel

16.5 in

Maximum Auger Clearance

21 in

Spoil Auger Diameter

18 in

Optional Cutting Widths

203, 254, 305 mm (8, 10, 12 in)


261-4859: T109 Hydraulic Side Shift, Standard Chain

261-4859: T109 Hydraulic Side Shift, Standard Chain

Designed for cutting narrow straight trenches in soil prior to laying electrical, telephone and cable lines, or water and gas pipe.



Cat

Standard Boom Length

36 in

Cutting Width

6 in

Chain Type

Standard

Required Hydraulics

Standard Flow

Overall Width

56.1 in

Overall Length

92.4 in

Weight

1076.1 lb

Overall Height

30.9 in

Optimal Hydraulic Flow

42-86 L/min (11-23 gpm)

Optimal Hydraulic Pressure

145-235 bar (2100-3400 psi)

Drive Shaft Speed at Maximum Flow

203 rpm

Side Shift Travel

16.5 in

Maximum Auger Clearance

21 in

Spoil Auger Diameter

18 in

Optional Cutting Widths

203, 254, 305 mm (8, 10, 12 in)


261-8557: T109 Manual Side Shift, Standard Chain

261-8557: T109 Manual Side Shift, Standard Chain

Designed for cutting narrow straight trenches in soil prior to laying electrical, telephone and cable lines, or water and gas pipe.



Cat

Standard Boom Length

36 in

Cutting Width

8 in

Chain Type

Standard

Required Hydraulics

Standard Flow

Overall Width

56.1 in

Overall Length

92.4 in

Weight

1028 lb

Overall Height

30.9 in

Optimal Hydraulic Flow

42-86 L/min (11-23 gpm)

Optimal Hydraulic Pressure

145-235 bar (2100-3400 psi)

Drive Shaft Speed at Maximum Flow

203 rpm

Side Shift Travel

16.5 in

Maximum Auger Clearance

21 in

Spoil Auger Diameter

18 in

Optional Cutting Widths

152, 254, 305 mm (6, 10, 12 in)


261-8558: T109 Hydraulic Side Shift, Standard Chain

261-8558: T109 Hydraulic Side Shift, Standard Chain

Designed for cutting narrow straight trenches in soil prior to laying electrical, telephone and cable lines, or water and gas pipe.



Cat

Standard Boom Length

36 in

Cutting Width

8 in

Chain Type

Standard

Required Hydraulics

Standard Flow

Overall Width

56.1 in

Overall Length

92.4 in

Weight

1091.9 lb

Overall Height

30.9 in

Optimal Hydraulic Flow

42-86 L/min (11-23 gpm)

Optimal Hydraulic Pressure

145-235 bar (2100-3400 psi)

Drive Shaft Speed at Maximum Flow

203 rpm

Side Shift Travel

16.5 in

Maximum Auger Clearance

21 in

Spoil Auger Diameter

18 in

Optional Cutting Widths

152, 254, 305 mm (6, 10, 12 in)


261-8559: T109 Manual Side Shift, Combo Chain

261-8559: T109 Manual Side Shift, Combo Chain

Designed for cutting narrow straight trenches in soil prior to laying electrical, telephone and cable lines, or water and gas pipe.



Cat

Standard Boom Length

36 in

Cutting Width

6 in

Chain Type

Combo

Required Hydraulics

Standard Flow

Overall Width

56.1 in

Overall Length

92.4 in

Weight

1035.1 lb

Overall Height

30.9 in

Optimal Hydraulic Flow

42-86 L/min (11-23 gpm)

Optimal Hydraulic Pressure

145-235 bar (2100-3400 psi)

Drive Shaft Speed at Maximum Flow

203 rpm

Side Shift Travel

16.5 in

Maximum Auger Clearance

21 in

Spoil Auger Diameter

18 in

Optional Cutting Widths

203, 254, 305 mm (8, 10, 12 in)


261-8561: T109 Manual Side Shift, Rock-Frost Chain

261-8561: T109 Manual Side Shift, Rock-Frost Chain

Designed for cutting narrow straight trenches in soil prior to laying electrical, telephone and cable lines, or water and gas pipe.



Cat

Standard Boom Length

36 in

Cutting Width

6 in

Chain Type

Rockfrost

Required Hydraulics

Standard Flow

Overall Width

56.1 in

Overall Length

92.4 in

Weight

1063.9 lb

Overall Height

30.9 in

Optimal Hydraulic Flow

42-86 L/min (11-23 gpm)

Optimal Hydraulic Pressure

145-235 bar (2100-3400 psi)

Drive Shaft Speed at Maximum Flow

203 rpm

Side Shift Travel

16.5 in

Maximum Auger Clearance

21 in

Spoil Auger Diameter

18 in

Optional Cutting Widths

203, 254, 305 mm (8, 10, 12 in)


261-8562: T109 Hydraulic Side Shift, Rock-Frost Chain

261-8562: T109 Hydraulic Side Shift, Rock-Frost Chain

Designed for cutting narrow straight trenches in soil prior to laying electrical, telephone and cable lines, or water and gas pipe.



Cat

Standard Boom Length

36 in

Cutting Width

6 in

Chain Type

Rockfrost

Required Hydraulics

Standard Flow

Overall Width

56.1 in

Overall Length

92.4 in

Weight

1128.1 lb

Overall Height

30.9 in

Optimal Hydraulic Flow

42-86 L/min (11-23 gpm)

Optimal Hydraulic Pressure

145-235 bar (2100-3400 psi)

Drive Shaft Speed at Maximum Flow

203 rpm

Side Shift Travel

16.5 in

Maximum Auger Clearance

21 in

Spoil Auger Diameter

18 in

Optional Cutting Widths

203, 254, 305 mm (8, 10, 12 in)


261-8563: T109 Manual Side Shift, Terminator Chain

261-8563: T109 Manual Side Shift, Terminator Chain

Designed for cutting narrow straight trenches in soil prior to laying electrical, telephone and cable lines, or water and gas pipe.



Cat

Standard Boom Length

36 in

Cutting Width

6 in

Chain Type

Terminator

Required Hydraulics

Standard Flow

Overall Width

56.1 in

Overall Length

92.4 in

Weight

1011.9 lb

Overall Height

30.9 in

Optimal Hydraulic Flow

42-86 L/min (11-23 gpm)

Optimal Hydraulic Pressure

145-235 bar (2100-3400 psi)

Drive Shaft Speed at Maximum Flow

203 rpm

Side Shift Travel

16.5 in

Maximum Auger Clearance

21 in

Spoil Auger Diameter

18 in

Optional Cutting Widths

203, 254, 305 mm (8, 10, 12 in)


Key

Key

Factory Fit

This part is designed to fit your Cat equipment based on the manufacturer’s specifications.

Any changes to the manufacturer’s configuration might result in the product not fitting your Cat equipment. Please consult your Cat Dealer before purchasing to ensure that this part is appropriate for your Cat equipment in its current condition and assumed configuration. This indicator cannot guarantee compatibility for all parts.

Remanufactured

Non-Returnable

Kit

Replaced

Remanufactured

Non-Returnable

Kit

Replaced